Model | HTS-240WD | HTS-320WD | HTS-340WD | HTS-420WD | HTS-460WD | HTS-540WD | HTS-620WD | ||
nominal cooling capacity | kw | 240 | 316 | 344 | 420 | 460 | 542 | 626.8 | |
ton | 68.24 | 87 | 97.81 | 119.42 | 130.79 | 154.11 | 178.22 | ||
power consumption | kw | 60 | 76 | 84 | 102 | 112 | 126 | 146 | |
power source | 3PH 380V 50HZ | ||||||||
refrigerant | type | R22 | |||||||
Charge | kg | 22*2 | 27*2 | 33*2 | 38*2 | 42*2 | 48*2 | 55*2 | |
control | Thermostatic expansion valve | ||||||||
compressor | type | Semi-hermetic screw | |||||||
power | kw | 30*2 | 38*2 | 42*2 | 51*2 | 56*2 | 63*2 | 73*2 | |
Start mode | Y-� | ||||||||
Energy regulation | % | 0-25-50-75-100 | |||||||
evaporator | type |
Shell and tube |
|||||||
Flow rate |
m3/h |
41 |
52.2 |
59 |
72.2 |
79 |
91.2 |
99.4 |
|
Water resistance |
KPa |
38 |
42 |
42 |
45 |
46 |
43 |
45 |
|
inlet and outlet |
inch |
4 |
4 |
5 |
5 |
6 |
6 |
8 |
|
condenser |
type |
|
Shell and tube |
||||||
Flow rate |
m3/h |
50 |
64.6 |
73.2 |
90.4 |
98.4 |
112 |
123.4 |
|
Water resistance |
KPa |
39 |
41 |
42 |
42 |
42 |
45 |
48 |
|
inlet and outlet |
inch |
4 |
4 |
5 |
6 |
4*2 |
4*4 |
5*2 |
|
Safety devices |
Inner thermostat for compressor motor, unit overload relay, high and low pressure switch, freeze protection thermostat, phase protection relay, discharge gas thermostat, flow switch |
||||||||
dimension |
Length |
mm |
2800 |
2800 |
2950 |
2950 |
3150 |
3480 |
3480 |
Depth |
mm |
780 |
780 |
810 |
810 |
850 |
875 |
895 |
|
Height |
mm |
1650 |
1650 |
1650 |
1650 |
1750 |
1850 |
1850 |
|
weigh |
kg |
1800 |
1850 |
2200 |
2450 |
2650 |
2800 |
3450 |
Remarks:
the nominal cooling capacities are based on the following conditions:
coolant temperature difference 3C to 8C;
cooling water inlet 25C, outlet 30C, temperature difference 3.5C to 10C;
If you have any special requirements, please keep us noted.
Specifications, appearances and dimensions are subject to change without notice.